KRS-G75螺旋式冰水機組冷凍特性表
R22 |
凝縮溫度和表壓力
|
冰水出口溫度℃
|
冰水出入口溫差℃
|
冷卻能力
Kcal/Hr.
|
冷凍噸
RT
|
輸入電力
KW
|
冰水器水量
|
30℃
11.2kg/c㎡
(160 PSI)
|
12.5
|
5.84
|
288,510
|
95.4
|
58.4
|
(1)
設計參考值(約)
53.2M /HR
水壓
Max.3kg/c㎡
(2)
依據設計參考水量和本表資料之冷卻能力可計算出冰水出入口溫差。
|
10.0
|
5.30
|
265,000
|
87.6
|
57.5
|
7.5
|
4.72
|
241,890
|
80.0
|
56.6
|
5.0
|
4.28
|
218,760
|
72.3
|
56.4
|
35℃
12.9kg/c㎡
(184 PSI)
|
12.5
|
5.46
|
271,830
|
89.9
|
66.5
|
10.0
|
5.00
|
249,090
|
82.4
|
65.4
|
7.5
|
4.56
|
226,330
|
74.8
|
64.5
|
5.0
|
4.12
|
204,730
|
67.7
|
64.2
|
40℃
14.7kg/c㎡
(210 PSI)
|
12.5
|
5.20
|
258,570
|
85.5
|
71.4
|
10.0
|
4.73
|
236,950
|
78.4
|
70.7
|
7.5
|
4.28
|
216,100
|
71.5
|
69.9
|
5.0
|
3.87
|
196,000
|
64.8
|
69.8
|
45℃
16.7kg/c㎡
(239 PSI)
|
12.5
|
4.94
|
239,980
|
79.4
|
79.4
|
10.0
|
4.48
|
219,130
|
72.5
|
78.3
|
7.5
|
4.05
|
198,660
|
65.7
|
77.4
|
5.0
|
3.66
|
179,700
|
59.4
|
77.1
|
凝縮器冷卻水量設計參考值
|
冷卻水入口溫度 ℃
|
22
|
27
|
32
|
37
|
冷卻水量(約)
|
63.8M  /HR
|
冷卻水出口溫度 ℃
|
27
|
32
|
37
|
42
|
水壓
|
Max.4kg/c㎡
|
凝縮溫度 ℃
|
30
|
35
|
40
|
45
|
註1:本資料系敝公司冷凍特性性能試驗數據。
註2:可容許檢驗值±5%
|